Commons

Letzte Einträge:
2022-11-22
13:05

Details des Eintrags - Ähnliche Datensätze
2022-11-16
09:15
OpenAccess [GSI-2022-00809] Contribution to a conference proceedings/Contribution to a book
;
Transverse Excitation and Applications for Beam Control
Proceedings of the 13th International Particle Accelerator Conference, IPAC2022
13th International Particle Accelerator Conference, IPAC22, BangkokBangkok, Thailand, 12 Jun 2022 - 17 Jun 20222022-06-122022-06-17
JACoW Publishing, Geneva, Switzerland 3 pp. () [10.18429/JACOW-IPAC2022-MOPOPT011]
Transverse excitation of stored particle beams is required for a number of applications in accelerators. Using a time-varying, transverse electric field with a dedicated frequency spectrum, the amplitude and coherence of betatron oscillations can be increased in a controlled manner. [...]
OpenAccess: Download fulltextPDF;

Details des Eintrags - Ähnliche Datensätze
2022-11-09
13:25

Details des Eintrags - Ähnliche Datensätze
2022-10-04
08:49

Details des Eintrags - Ähnliche Datensätze
2022-06-21
10:11
[GSI-2022-00577] Dataset

Fast-neutron-induced fission cross section of Pu(242) measured at the neutron time-of-flight facility nELBE
This dataset includes the processed data of the fast neutron-induced fission of Pu(242) experiement performed in November 2014 at the neutron time-of-flight facility nELBE which was published in T. Kögler et al., Phys. [...]

Details des Eintrags - Ähnliche Datensätze
2022-06-02
07:23
OpenAccess [GSI-2022-00553] Contribution to a conference proceedings/Contribution to a book
; ; ; et al
Commissioning of the Cryogenic Current Comparator (CCC) at CRYRING
Proceedings of the 10th International Beam Instrumentation Conference, IBIC2021, Pohang, Rep. of Korea
10th International Beam Instrumentation Conference, IBIC 2021, PohangPohang, Republic of Corea, 24 May 2021 - 28 May 20212021-05-242021-05-28
JACoW Publishing, Geneva, Switzerland 4 pages () [10.18429/JACOW-IBIC2021-WEOB02]
Accurate non-destructive measurement of the absolute intensity of weak ion beams ( 1 uA) in storage rings is often restricted to special beam conditions and, even then, is associated with large uncertainties and tedious calibration procedures. However, experiments with rare ions in particular depend on excellent current resolution. [...]
OpenAccess: Download fulltextPDF;

Details des Eintrags - Ähnliche Datensätze
2022-01-14
10:40
OpenAccess [GSI-2022-00086] Contribution to a conference proceedings/Contribution to a book
; ; ; et al
Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams
Proceedings of the 10th International Beam Instrumentation Conference, IBIC2021, Pohang, Rep. of Korea
10th International Beam Instrumentation Conference, WEPP16, PohangPohang, Korea, 24 May 2021 - 28 May 20212021-05-242021-05-28
JACoW Publishing, Geneva, Switzerland 407-411 () [10.18429/JACoW-IBIC2021-WEPP16]
A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. [...]
OpenAccess: Download fulltextPDF;

Details des Eintrags - Ähnliche Datensätze
2021-10-14
10:47

Details des Eintrags - Ähnliche Datensätze
2021-05-21
10:24

Details des Eintrags - Ähnliche Datensätze
2021-05-17
15:05

Details des Eintrags - Ähnliche Datensätze