TI  - Measurement of UNILAC and SIS18 proton performance
IS  - Report
M1  - GSI-2016-03764
M1  - Report
SP  - 3 Seiten
PY  - 2016
AB  - On July 16th 2016 the UNILAC and SIS18 proton performance has been measured. Due to scheduled maintenance works of the UNILAC's rf-system, the post-stripper energy was restricted to 5.9 MeV and accordingly the beam quality suffered considerably from the interruption of the periodic focusing system. This limitation will not be any longer in future beam times. Six single-gap resonators were used for acceleration to 10.7 MeV. After an optimization of the multi-turn injection \pmb1.2·10<sup>11</sup> protons were extracted form the SIS18.