@PHDTHESIS{Ebrahimi:218424,
      author       = {Ebrahimi, Mohammad Sadegh},
      title        = {{N}on-{D}estructive {D}etection and {R}esistive {C}ooling
                      of {H}ighly-{C}harged-{I}on {E}nsembles for {P}recision
                      {S}pectroscopy in the {ARTEMIS} {P}enning {T}rap},
      school       = {Ruprecht-Karls-Universität Heidelberg},
      type         = {Dissertation},
      address      = {Heidelberg},
      publisher    = {Heidelberg University Library},
      reportid     = {GSI-2019-00402},
      pages        = {154 S.},
      year         = {2018},
      note         = {Dissertation, Ruprecht-Karls-Universität Heidelberg, 2018},
      abstract     = {An important aspect of precision measurements in a Penning
                      trap is the ability to cool the confined particles to
                      cryogenic temperatures, which reduces the measurement
                      uncertainty. The ARTEMIS Penning trap, located at the HiTrap
                      facility at GSI, is designed to measure the g−factor of
                      heavy to medium highly charged ions, such as 40Ar13+ and
                      209Bi82+, using microwave-laser double resonance
                      spectroscopy on a ppb level of accuracy. The foreseen
                      measurement scheme involves spectroscopy of a large number
                      of confined particles in the form of an ensemble, typically
                      of the order of 105 ions. This thesis presents the
                      development and upgrades of the non-destructive detection
                      system of ARTEMIS, which is also used for resistive ion
                      cooling through dissipative interaction with the effective
                      resistance of the detection system. A theoretical treatment
                      of resistive cooling of an ion ensemble created in the
                      creation trap of ARTEMIS was performed and test with
                      different ion ensembles.},
      cin          = {ATP},
      cid          = {I:(DE-Ds200)ATP-20051214OR020},
      pnm          = {6211 - Extreme States of Matter: From Cold Ions to Hot
                      Plasmas (POF3-621)},
      pid          = {G:(DE-HGF)POF3-6211},
      typ          = {PUB:(DE-HGF)11},
      urn          = {urn:nbn:de:bsz:16-heidok-244672},
      doi          = {10.11588/heidok.00024467},
      url          = {https://repository.gsi.de/record/218424},
}