% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@TECHREPORT{Gmry:347488,
author = {Gömöry, Fedor and Dhallé, Marc},
othercontributors = {Kade, Andreas and Winkler, Tiemo},
title = {{HTS} {N}uclotron {C}able {P}roduced [{IFAST}-{MS}36
{M}ilestone {R}eport]},
volume = {MS36},
number = {Zenodo:7995185},
publisher = {Zenodo},
reportid = {GSI-2023-00987, Zenodo:7995185},
series = {IFAST Milestone Report},
pages = {9},
year = {2023},
abstract = {Two samples of the Nuclotron CORT cable were manufactured
and tested for their magnetization loss. The cables were
designed to have a critical current of 1350 A at 77.3 K and
around 10 kA at 4.2 K. The cable was made using commercial
REBCO coated conductor from a non-European manufacturer,
which had excellent mechanical properties. The experiments
were conducted at IEE Bratislava and at University of Twente
in Enschede at 77.3 K and 4.2 K, respectively. The results
confirm the expectation that there are negligible electrical
contacts between the copper-stabilized tape strands and that
it is possible to estimate hysteresis loss analytically for
accelerator-magnet-relevant operating conditions.},
cin = {SCM},
cid = {I:(DE-Ds200)SCM-20110830OR134},
pnm = {621 - Accelerator Research and Development (POF4-621) /
I.FAST - Innovation Fostering in Accelerator Science and
Technology (101004730)},
pid = {G:(DE-HGF)POF4-621 / G:(EU-Grant)101004730},
experiment = {$EXP:(DE-Ds200)External_experiment-20200803$},
typ = {PUB:(DE-HGF)3 / PUB:(DE-HGF)29},
doi = {10.5281/ZENODO.7995185},
url = {https://repository.gsi.de/record/347488},
}