000356836 001__ 356836
000356836 005__ 20250717224054.0
000356836 0247_ $$2doi$$a10.1088/1748-0221/19/02/C02056
000356836 0247_ $$2datacite_doi$$a10.15120/GSI-2025-00219
000356836 0247_ $$2WOS$$aWOS:001181996100007
000356836 037__ $$aGSI-2025-00219
000356836 041__ $$aEnglish
000356836 082__ $$a610
000356836 1001_ $$0P:(DE-Ds200)OR2989$$aMichel, J.$$b0
000356836 245__ $$aNew electronics for the HADES MDC drift chambers
000356836 260__ $$aLondon$$bInst. of Physics$$c2024
000356836 3367_ $$2DRIVER$$aarticle
000356836 3367_ $$2DataCite$$aOutput Types/Journal article
000356836 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1752750704_898612
000356836 3367_ $$2BibTeX$$aARTICLE
000356836 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000356836 3367_ $$00$$2EndNote$$aJournal Article
000356836 520__ $$aThe drift chambers of the HADES experiment at SIS-18 at GSI, Darmstadt/Germany, form the main tracking system of the spectrometer. Designed more than twenty years ago, the whole front-end electronics chain is being replaced with state-of-the-art electronics to cope with the increasing failure rate of the old electronics and with advanced requirements of the experiment, e.g. the trigger rate. The new analog signal processing is based on the PASTTREC ASIC, developed for the Straw Tube Tracker of the PANDA Experiment. The digitization of data happens in FPGA-based TDCs. The main challenges of the project are the strict spatial constraints given by the experiment setup to place the front-end boards and the noise sensitivity of the large area gas detectors. In addition, the power consumption needed to be kept low due to thermal constraints.
000356836 536__ $$0G:(DE-HGF)POF4-622$$a622 - Detector Technologies and Systems (POF4-622)$$cPOF4-622$$fPOF IV$$x0
000356836 588__ $$aDataset connected to CrossRef, Journals: repository.gsi.de
000356836 693__ $$0EXP:(DE-Ds200)S520-20200803$$1EXP:(DE-Ds200)HAD-20200803$$5EXP:(DE-Ds200)S520-20200803$$aHAD$$eS520: HADES - V (POF3-612; HAD)$$x0
000356836 7001_ $$aGniazdowski, T.$$b1
000356836 7001_ $$aGuzmán, A.$$b2
000356836 7001_ $$aMatejcek, F.$$b3
000356836 7001_ $$aMüntz, C.$$b4
000356836 7001_ $$aSvintozelskyi, V.$$b5
000356836 7001_ $$0P:(DE-Ds200)OR3337$$aWendisch, Christian$$b6$$ugsi
000356836 7001_ $$0P:(DE-Ds200)OR1258$$aStroth, J.$$b7$$ugsi
000356836 773__ $$0PERI:(DE-600)2235672-1$$a10.1088/1748-0221/19/02/C02056$$gVol. 19, no. 02, p. C02056 -$$n02$$pC02056 -$$tJournal of Instrumentation$$v19$$x1748-0221$$y2024
000356836 8564_ $$uhttps://repository.gsi.de/record/356836/files/Michel_2024_J._Inst._19_C02056.pdf$$yOpenAccess
000356836 8564_ $$uhttps://repository.gsi.de/record/356836/files/Michel_2024_J._Inst._19_C02056.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000356836 909CO $$ooai:repository.gsi.de:356836$$pdriver$$pVDB$$popen_access$$pdnbdelivery$$popenaire
000356836 9101_ $$0I:(DE-Ds200)20121206GSI$$6P:(DE-Ds200)OR3337$$aGSI Helmholtzzentrum für Schwerionenforschung GmbH$$b6$$kGSI
000356836 9101_ $$0I:(DE-Ds200)20121206GSI$$6P:(DE-Ds200)OR1258$$aGSI Helmholtzzentrum für Schwerionenforschung GmbH$$b7$$kGSI
000356836 9131_ $$0G:(DE-HGF)POF4-622$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vDetector Technologies and Systems$$x0
000356836 9141_ $$y2024
000356836 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2024-12-06
000356836 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000356836 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000356836 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bJ INSTRUM : 2022$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)0430$$2StatID$$aNational-Konsortium$$d2024-12-06$$wger
000356836 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2024-12-06
000356836 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2024-12-06
000356836 920__ $$lyes
000356836 9201_ $$0I:(DE-Ds200)HAD-20080822OR103$$kHAD$$lHADES$$x0
000356836 9201_ $$0I:(DE-Ds200)Coll-GSI-HADES$$kHADES@GSI$$lCollaboration GSI: HADES$$x1
000356836 9201_ $$0I:(DE-Ds200)Coll-FAIR-HADES$$kHADES@FAIR$$lCollaboration FAIR: HADES$$x2
000356836 980__ $$ajournal
000356836 980__ $$aVDB
000356836 980__ $$aI:(DE-Ds200)HAD-20080822OR103
000356836 980__ $$aI:(DE-Ds200)Coll-GSI-HADES
000356836 980__ $$aI:(DE-Ds200)Coll-FAIR-HADES
000356836 980__ $$aUNRESTRICTED
000356836 9801_ $$aFullTexts