% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Michel:356836,
author = {Michel, J. and Gniazdowski, T. and Guzmán, A. and
Matejcek, F. and Müntz, C. and Svintozelskyi, V. and
Wendisch, Christian and Stroth, J.},
title = {{N}ew electronics for the {HADES} {MDC} drift chambers},
journal = {Journal of Instrumentation},
volume = {19},
number = {02},
issn = {1748-0221},
address = {London},
publisher = {Inst. of Physics},
reportid = {GSI-2025-00219},
pages = {C02056 -},
year = {2024},
abstract = {The drift chambers of the HADES experiment at SIS-18 at
GSI, Darmstadt/Germany, form the main tracking system of the
spectrometer. Designed more than twenty years ago, the whole
front-end electronics chain is being replaced with
state-of-the-art electronics to cope with the increasing
failure rate of the old electronics and with advanced
requirements of the experiment, e.g. the trigger rate. The
new analog signal processing is based on the PASTTREC ASIC,
developed for the Straw Tube Tracker of the PANDA
Experiment. The digitization of data happens in FPGA-based
TDCs. The main challenges of the project are the strict
spatial constraints given by the experiment setup to place
the front-end boards and the noise sensitivity of the large
area gas detectors. In addition, the power consumption
needed to be kept low due to thermal constraints.},
cin = {HAD / HADES@GSI / HADES@FAIR},
ddc = {610},
cid = {I:(DE-Ds200)HAD-20080822OR103 / I:(DE-Ds200)Coll-GSI-HADES
/ I:(DE-Ds200)Coll-FAIR-HADES},
pnm = {622 - Detector Technologies and Systems (POF4-622)},
pid = {G:(DE-HGF)POF4-622},
experiment = {EXP:(DE-Ds200)S520-20200803},
typ = {PUB:(DE-HGF)16},
UT = {WOS:001181996100007},
doi = {10.1088/1748-0221/19/02/C02056},
url = {https://repository.gsi.de/record/356836},
}