@INPROCEEDINGS{AguarBartolome:357445,
      author       = {Aguar Bartolome, Patricia and Bleile, Alexander and
                      Kaether, Florian and Janke, Matthias and Meier, Jan and
                      Pyka, Niels and Roux, Christian and Spiller, Peter and
                      Streicher, Branislav and Szwangruber, Anna and Szwangruber,
                      Piotr and Wilfert, Stefan and Winkler, Tiemo},
      editor       = {Pilat, Fulvia and Fischer, Wolfram and Saethre, Robert and
                      Anisimov, Petr and Andrian, Ivan},
      title        = {{S}uperconducting magnet string test for the {SIS}100
                      accelerator of {FAIR}},
      publisher    = {JACoW Publishing},
      reportid     = {GSI-2025-00402},
      pages        = {1718-1721 pages1.7 MB},
      year         = {2024},
      note         = {Published by JACoW Publishing under the terms of the
                      Creative Commons Attribution 4.0 license.},
      abstract     = {The SIS100 accelerator, currently under construction in
                      Darmstadt (Germany), consists of six arc and straight
                      sections. Each of the six cryogenic arc sections comprises
                      fourteen regularly repeating optical cells (lattice). Each
                      standard cell includes two dipole magnets and two quadrupole
                      units integrated in a quadrupole doublet module. The SIS100
                      String Test technically represents one standard cell of the
                      arc section of the SIS100, terminated by and End Cap and a
                      Bypass Line as a representation of the end of the arc
                      section. The purpose of the SIS100 String Test is to
                      validate all technical systems such as cryogenics, vacuum,
                      interlock and quench detection and investigate their
                      collective behavior. A wide spectrum of tests will be
                      performed during cool down, powering at operational
                      conditions and warm up. Additionally, the experience gained
                      during the SIS100 String Test will be crucial for the
                      installation, commissioning and operation of the SIS100. The
                      planning, installation process and first experimental
                      results of the String Test will be presented.},
      month         = {May},
      date          = {2024-05-19},
      organization  = {15th International Particle
                       Accelerator Conference, Nashville
                       (USA), 19 May 2024 - 24 May 2024},
      keywords     = {Accelerator Physics (Other) / mc4-hadron-accelerators -
                      MC4: Hadron Accelerators (Other) / MC4.A24 - MC4.A24
                      Accelerators and Storage Rings, Other (Other)},
      cin          = {SCM / CRY / VAC / SYS},
      cid          = {I:(DE-Ds200)SCM-20110830OR134 /
                      I:(DE-Ds200)CRY-20121002OR224 /
                      I:(DE-Ds200)VAC-20121002OR253 /
                      I:(DE-Ds200)SYS-20121002OR231},
      pnm          = {6G12 - FAIR (GSI) (POF4-6G12)},
      pid          = {G:(DE-HGF)POF4-6G12},
      experiment   = {$EXP:(DE-Ds200)Experiment_without_proposal_number-20200803$},
      typ          = {PUB:(DE-HGF)8},
      doi          = {10.18429/JACOW-IPAC2024-TUPS34},
      url          = {https://repository.gsi.de/record/357445},
}