000357723 001__ 357723
000357723 005__ 20250227110547.0
000357723 0247_ $$2doi$$a10.18429/JACOW-LINAC2022-TUPOJO06
000357723 0247_ $$2datacite_doi$$a10.15120/GSI-2025-00415
000357723 037__ $$aGSI-2025-00415
000357723 041__ $$aEnglish
000357723 1001_ $$0P:(DE-Ds200)OR6682$$aSieber, Thomas$$b0$$eCorresponding author
000357723 1112_ $$aInternational Linear Accelerator Conference$$cLiverpool$$d2022-08-28 - 2022-09-02$$wUK
000357723 245__ $$aDesign and Test of Beam Diagnostics Equipment for the FAIR Proton Linac
000357723 250__ $$a31st
000357723 260__ $$aGeneva, Switzerland$$bJACoW Publishing$$c2022
000357723 29510 $$aProceedings of the 31st International Linear Accelerator Conference, LINAC2022, Liverpool, UK
000357723 300__ $$a4 pages
000357723 3367_ $$2ORCID$$aCONFERENCE_PAPER
000357723 3367_ $$033$$2EndNote$$aConference Paper
000357723 3367_ $$2BibTeX$$aINPROCEEDINGS
000357723 3367_ $$2DRIVER$$aconferenceObject
000357723 3367_ $$2DataCite$$aOutput Types/Conference Paper
000357723 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1739883615_2180750
000357723 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$mcontb
000357723 500__ $$aPublished by JACoW Publishing under the terms of the Creative Commons Attribution 4.0 International license.
000357723 520__ $$aA dedicated proton injector Linac (pLinac) for the Facility of Antiproton and Ion Research (FAIR) at GSI, Darmstadt, is currently under construction. It will pro-vide a 68 MeV, up to 70 mA proton beam at a duty cycle of max. 35µs / 4 Hz for the SIS18 synchrotron, using the UNILAC transfer beamline. After further acceleration in SIS100, the protons are mainly used for antiproton production at the Antiproton Annihilation Darmstadt (PANDA) experiment. The Linac will operate at 325 MHz and consists of a novel so called ’Ladder’ RFQ type, followed by a chain of CH-cavities, partially coupled by rf-coupling cells. In this paper we present the beam diagnostics system for the pLinac with special emphasis on the Secondary Electron Emission (SEM) Grids and the Beam Position Monitor (BPM) system. We also describe design and status of our diagnostics testbench for stepwise Linac commissioning, which includes an energy spectrometer with associated optical system. The BPMs and SEM grids have been tested with proton and argon beam during several beamtimes in 2022. The results of these experiments are presented.
000357723 536__ $$0G:(DE-HGF)POF4-621$$a621 - Accelerator Research and Development (POF4-621)$$cPOF4-621$$fPOF IV$$x0
000357723 588__ $$aDataset connected to DataCite
000357723 650_7 $$2Other$$aAccelerator Physics
000357723 650_7 $$2Other$$aProton and Ion Accelerators and Applications
000357723 693__ $$0EXP:(DE-Ds200)no_experiment-20200803$$1EXP:(DE-Ds200)theory-20200803$$5EXP:(DE-Ds200)no_experiment-20200803$$atheory$$eno experiment theory work (theory)$$x0
000357723 7001_ $$aBustinduy, Ibon$$b1
000357723 7001_ $$0P:(DE-Ds200)OR0310$$aForck, Peter$$b2$$ugsi
000357723 7001_ $$aHerranz, Juan$$b3
000357723 7001_ $$0P:(DE-Ds200)OR0589$$aKleffner, Carl$$b4$$ugsi
000357723 7001_ $$aNavarro Fernandez, Araceli$$b5
000357723 7001_ $$aRodríguez Páramo, Angel$$b6
000357723 7001_ $$0P:(DE-Ds200)OR1313$$aUdrea, Serban$$b7$$ugsi
000357723 7001_ $$aMcIntosh, Peter$$b8$$eEditor
000357723 7001_ $$00000-0001-8288-1216$$aBurt, Graeme$$b9$$eEditor
000357723 7001_ $$00000-0001-6346-5989$$aApsimon, Robert$$b10$$eEditor
000357723 7001_ $$aSchaa, Volker R. W.$$b11$$eEditor
000357723 773__ $$a10.18429/JACOW-LINAC2022-TUPOJO06
000357723 8564_ $$uhttps://repository.gsi.de/record/357723/files/tupojo06.pdf$$yOpenAccess
000357723 8564_ $$uhttps://repository.gsi.de/record/357723/files/tupojo06.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000357723 909CO $$ooai:repository.gsi.de:357723$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000357723 9101_ $$0I:(DE-Ds200)20121206GSI$$6P:(DE-Ds200)OR6682$$aGSI Helmholtzzentrum für Schwerionenforschung GmbH$$b0$$kGSI
000357723 9101_ $$0I:(DE-Ds200)20121206GSI$$6P:(DE-Ds200)OR0310$$aGSI Helmholtzzentrum für Schwerionenforschung GmbH$$b2$$kGSI
000357723 9101_ $$0I:(DE-Ds200)20121206GSI$$6P:(DE-Ds200)OR0589$$aGSI Helmholtzzentrum für Schwerionenforschung GmbH$$b4$$kGSI
000357723 9101_ $$0I:(DE-Ds200)20121206GSI$$6P:(DE-Ds200)OR1313$$aGSI Helmholtzzentrum für Schwerionenforschung GmbH$$b7$$kGSI
000357723 9131_ $$0G:(DE-HGF)POF4-621$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vAccelerator Research and Development$$x0
000357723 9141_ $$y2022
000357723 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000357723 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000357723 920__ $$lno
000357723 9201_ $$0I:(DE-Ds200)BEA-20051214OR061$$kBEA$$lBeam Diagnostics$$x0
000357723 980__ $$acontrib
000357723 980__ $$aVDB
000357723 980__ $$aUNRESTRICTED
000357723 980__ $$acontb
000357723 980__ $$aI:(DE-Ds200)BEA-20051214OR061
000357723 9801_ $$aFullTexts