% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Darwish:364996,
author = {Darwish, Hasan and Altingun, Ali-Murteza and Andary, Julio
and Arnoldi-Meadows, Benedict and Baudot, Jerome and
Bertolone, Gregory and Besson, Auguste and Bialas, Norbert
and Braun, Christopher and Bugiel, Roma and Claus, Gilles
and Colledani, Claude and Deveaux, Michael and Dorokhov,
Andrei and Dozière, Guy and Bitar, Ziad El and Fröhlich,
Ingo and Goffe, Mathieu and Gutsche, Benedikt and Himmi,
Abdelkader and Hu-Guo, Christine and Jaaskelainen, Kimmo and
Keller, Oliver and Koziel, Michal and Matejcek, Franz and
Michel, Jan and Morel, Frederic and Müntz, Christian and
Pham, Hung and Schmidt, Christian Joachim and Schreiber,
Stefan and Schulz, Marvin and Specht, Matthieu and Stroth,
Joachim and Taka, Eva-dhidho and Valin, Isabelle and Zhao,
Yüe and Winter, Marc},
title = {{I}n-beam performance of neutron irradiated {MIMOSIS}-1
{CMOS} {M}onolithic {A}ctive {P}ixel {S}ensors},
journal = {Journal of Instrumentation},
volume = {20},
number = {08},
issn = {1748-0221},
address = {London},
publisher = {Inst. of Physics},
reportid = {GSI-2026-00349},
pages = {C08009},
year = {2025},
note = {Published by IOP Publishing Ltd on behalf of Sissa
Medialab. Original content from this work may be used under
the terms of the Creative Commons Attribution 4.0 licence},
abstract = {MIMOSIS is the CMOS Monolithic Active Pixel Sensor designed
for the Micro Vertex Detector (MVD) of the Compressed
Baryonic Matter (CBM) experiment currently under development
at FAIR. The sensors have to combine a spatial and a time
resolution of 5 mu m and 5 mu s, handle a peak hit rate of
similar to 80 MHz/cm(2), and to withstand Total Ionizing
radiation Doses (TID) of similar to 5 MRad and Non-Ionizing
Energy Loss (NIEL) fluences of similar to 7 x 10(13)
n(eq)/cm(2) before being replaced. Prior to their use in the
experiment, the sensors undergo lab and in-beam tests, to
qualify their performance in charged particles detection. In
this work we present the sensor design and concept, a
summary of its requirements as a candidate for the CBM-MVD,
followed by the performance results of the first full-size
prototype, MIMOSIS-1, from in-beam tests done at DESY and
CERN, after being irradiated to different TID and NIEL
fluences.},
month = {Feb},
date = {2025-02-04},
organization = {20th Anniversary Trento Workshop on
Advanced Silicon Radiation Detectors,
Trento (Italy), 4 Feb 2025 - 6 Feb
2025},
cin = {DTL / HAD / CBM@FAIR},
ddc = {610},
cid = {I:(DE-Ds200)DTL-20051214OR031 /
I:(DE-Ds200)HAD-20080822OR103 / I:(DE-Ds200)Coll-FAIR-CBM},
pnm = {622 - Detector Technologies and Systems (POF4-622) /
HGS-HIRe - HGS-HIRe for FAIR (HGS-HIRe)},
pid = {G:(DE-HGF)POF4-622 / G:(DE-Ds200)HGS-HIRe},
experiment = {$EXP:(DE-Ds200)External_experiment-20200803$},
typ = {PUB:(DE-HGF)8 / PUB:(DE-HGF)16},
doi = {10.1088/1748-0221/20/08/C08009},
url = {https://repository.gsi.de/record/364996},
}