@INPROCEEDINGS{Schwickert:66651,
      author       = {Schwickert, Marcus and Bräuning, Harald and Kurian, Febin
                      and Reeg, Hansjörg and Reiter, Andreas and Geithner, R. and
                      Vodel, Wolfgang and Neubert, R.},
      title        = {{B}eam {C}urrent {M}onitors for {FAIR}},
      reportid     = {GSI-2014-01543},
      isbn         = {978-3-95450-132-8},
      pages        = {3483-3485},
      year         = {2014},
      comment      = {Proceedings of IPAC2014, Dresden, Germany},
      booktitle     = {Proceedings of IPAC2014, Dresden,
                       Germany},
      abstract     = {The FAIR (Facility for Antiproton and Ion Research)
                      accelerator facility presently under construction at GSIwill
                      supply a wide range of beam intensities for
                      physicsexperiments. Design beam intensities range from
                      2.5×1013protons/cycle to be delivered to the pBar-target
                      andseparator for production of antiprotons, to beams of
                      e.g.109 ions/s in the case of slowly extracted beams.
                      Thelarge intensity range demands for dedicated beam
                      currentmonitors for precise, non-destructive beam
                      intensitymeasurements in the synchrotrons, transport lines
                      andstorage rings of the FAIR facility. This report
                      describesGSI developments of purpose-built beam
                      currentmonitors for the SIS100 synchrotron and
                      high-energybeam transport lines (HEBT) of FAIR.
                      Prototypemeasurements with a SQUID-based Cryogenic
                      CurrentComparator and a resonant beam charge transformer
                      arepresented, and possibilities for further upgrades
                      arediscussed.},
      month         = {Jun},
      date          = {2014-06-15},
      organization  = {5th International Particle Accelerator
                       Conference, Dresden (Germany), 15 Jun
                       2014 - 20 Jun 2014},
      cin          = {OPE / HIJ},
      cid          = {I:(DE-Ds200)OPE-20051214OR052 /
                      I:(DE-Ds200)HIJ-20110223OR115},
      pnm          = {PSP 2.3.6 Beam Diagnostics (PSP-2-3-6) / 53G -
                      Participation in FAIR (POF2-53G31)},
      pid          = {G:(DE-Ds200)PSP-2-3-6 / G:(DE-HGF)POF2-53G31},
      typ          = {PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
      url          = {https://repository.gsi.de/record/66651},
}