Home > Publications database > High Current Heavy Ion Beam Investigations at GSI-UNILAC |
Contribution to a conference proceedings/Contribution to a book | GSI-2025-00481 |
; ; ; ; ; ; ; ; ; ; ; ; ;
2022
JACoW Publishing
Geneva, Switzerland
Please use a persistent id in citations: doi:10.18429/JACOW-IPAC2022-MOPOST012 doi:10.15120/GSI-2025-00481
Abstract: The GSI Universal Linear Accelerator UNILAC and the synchrotron SIS18 will serve as injector for the upcoming FAIR-facility. The UNILAC-High Current Injector will be improved and modernized until FAIR is commissioned and the Alvarez poststripper accelerator is replaced. The reference heavy ion for future FAIR-operation is uranium, with highest intensity requirements. To re-establish uranium beam operation and to improve high current beam operation, different subjects have been explored in dedicated machine investigation campaigns. After a beam line modification in 2017 the RFQ-performance had deteriorated significantly; new rods have been installed and the RF-working point has been redefined. Also the Superlens-performance had become unsatisfactory; improved with a modified RF-coupler. With a pulsed hydrogen gas stripper target the uranium beam stripping efficiency could be increased by 65%. Various work has already been carried out to establish this stripper device in routine operation. With medium heavy ion beams a very high beam brilliance at the end of transfer line to SIS18 was achieved. Results of the measurement campaigns and the UNILAC upgrade activities will be presented.
Keyword(s): Accelerator Physics ; MC4: Hadron Accelerators
![]() |
The record appears in these collections: |