Abstract: The Compressed Baryonic Matter (CBM) experiment at the Facility for Antiproton and Ion Research (FAIR) in Darmstadt requires a highly accurate beam monitoring and time-zero (T0) system. This system needs to meet the requirements of the CBM time-of-flight (ToF) measurement system for both proton and heavy ion beams, while also serving as part of the fast beam abort system. To achieve these goals, a detector based on chemical vapor deposition (CVD) diamond technology has been proposed. In addition, new developments using Low Gain Avalanche Detectors (LGADs) are currently under evaluation. This contribution presents the current development status of the beam detector concept for the CBM experiment.