Journal Article GSI-2025-01220

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
A simple dynamic time-over-threshold circuit for high-resolution amplitude measurement



2026
Elsevier [Amsterdam]

Nuclear instruments & methods in physics research / Section A 1083, 171165 () [10.1016/j.nima.2025.171165]

Please use a persistent id in citations: doi:  doi:

Abstract: The dynamic time-over-threshold (dToT) method is a timing-based readout technique for pulse-height measurement of radiation detectors. After the leading-edge detection, the discriminator threshold is raised to allow precise pulse-height estimation over a wide dynamic range. A particularly simple circuit implementation of dToT is presented that delivers excellent amplitude resolution with minimal complexity. Experiments show that the resolution is sufficient to read out high-performance scintillators such as LaBr3:Ce without degrading their intrinsic energy resolution.

Classification:

Note: This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Contributing Institute(s):
  1. Experimentelektronik (EEL)
Research Program(s):
  1. 899 - ohne Topic (POF4-899) (POF4-899)
Experiment(s):
  1. no experiment theory work (theory)

Database coverage:
Medline ; Creative Commons Attribution CC BY 4.0 ; OpenAccess ; Clarivate Analytics Master Journal List ; Current Contents - Engineering, Computing and Technology ; Current Contents - Physical, Chemical and Earth Sciences ; Ebsco Academic Search ; Essential Science Indicators ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Private Institute collections > >WGF > >RED > EEL
Document types > Articles > Journal Article
Infrastructure > Experiment Electronics
Workflow collections > Public records
Publications database
Open Access

 Record created 2025-11-18, last modified 2025-11-24