| Home > GSI as publisher > Measurement of UNILAC and SIS18 proton performance |
| Report | GSI-2016-03764 |
; ; ; ; ; ;
2016
Please use a persistent id in citations: doi:10.15120/GSI-2016-03764
Report No.: Report
Abstract: On July 16th 2016 the UNILAC and SIS18 proton performance has been measured. Due to scheduled maintenance works of the UNILAC's rf-system, the post-stripper energy was restricted to 5.9~MeV and accordingly the beam quality suffered considerably from the interruption of the periodic focusing system. This limitation will not be any longer in future beam times. Six single-gap resonators were used for acceleration to 10.7~MeV. After an optimization of the multi-turn injection $\pmb{1.2\cdot10^{11}}$ protons were extracted form the SIS18.