Abstract: We have devised an experimental method and apparatus for the simultaneous nondestructive determination of the absolute ion number, ionkinetic energy, and length of bunches of charged particles. We have built and operated a corresponding electronic detector that is based oninduced charges and their subsequent low-noise amplification at cryogenic temperatures. We have performed measurements with bunchesof low-energy highly charged ions from an electron-beam ion source that show the capability of the methods and their implementation. Wediscuss requirements for, and applications of, such detectors with a particular view on the obtainable information and their sensitivity.
|